Cooling scheme |
Air-cooling type |
Cooling capacity (W) |
10300 |
Thermal capacity (W) |
2500 |
Circulated water |
Pure water (over 1μs/cm), distilled water, pure water, ethylene glycol (less than 30% density) |
Temperature control accuracy (°C) |
±0.1 |
Circulated water temperature range (fresh water) (°C) |
5 to 45 |
Circulated water temperature range (antifreeze) (°C) |
-5 to 45 |
Circulated water flow-rate range (L/min) |
20 to 70 |
Circulated water pressure range (Mpa) |
0.7 or less |
Ambient temperature (°C) |
-5 to 45 |
Type |
R-410A |
Filling amount (g) |
1350 |
Exterior dimensions (w/o casters) (mm) |
H1468 x W850 x D750 |
Paint color |
DIC G-260 (Munsell value: N7.5 equivalent) |
Weight (kg) |
135 |
Power voltage (V) |
3-phase AC200 to 230VAC |
Power consumption (kW) |
4.6 |
Current consumption (A) |
14.4 |
Breaker capacity (A) |
30 |
Power source capacity (kVA) |
7.6 |
Constituent equipment/Compressor |
Shutting tightly Roundabout system |
Constituent equipment/Condenser |
Parallel flow condenser type, forced air cooling system |
Constituent equipment/Cooler |
Plate-type heat exchanger |
Constituent equipment/Water pump |
Multistep spiral dipping mandrel |
Constituent equipment/Lift (m) |
51 |
Constituent equipment/Tank capacity (L) |
35 |
Constituent equipment/Coolant |
R-410A |
Safety circuitry/Compressor |
Motor protector |
Safety circuitry/Cooling cycle |
Pressure switch |
Safety circuitry/Circulated water circuit |
Water pressure sensor, low-water float switch |
Alarm output |
No voltage open-contact (AC250V/2A) |
Water temperature upper-limit alarm output |
No voltage open-contact (AC250V/2A) |
Water temperature lower-limit alarm output |
No voltage open-contact (AC250V/2A) |
Operation stop output |
No voltage open-contact (AC250V/2A) |
Pump output |
No voltage open-contact (AC250V/2A) |
Operation stop input |
No voltage input |
Error reset input |
No voltage input |
Emergency stop input |
No voltage input |
Ethernet (Communication standard) |
Ethernet 10BASE-T/100BASE-TX |
Ethernet (Communication protocol) |
Socket (TCP/IP), MC protocol (UDP/IP) |
Ethernet (IP address) |
IPv4 |
LCD (Settings menu) |
Operation mode/Circulated water temperature alarm/Timer/Settings/Custom settings/Input-output settings/Communication settings/Error history |
LCD (Circulated water temperature movement) |
Circulated water temperature rising/decreasing/stable trend |
LCD (Graphical display) |
Internal temperature graph, circulated water pressure graph |
LCD (Input/output monitor) |
Input 1 (3-point)/Output 1 (3-point)/Output 2 (2-point) |
LCD (Operation monitor) |
Compressor high-pressure/Compressor low-pressure/Circulated water pressure/Circulated water temperature/Compressor outlet temperature/Compressor inlet temperature/Circulated water flow-rate/Circulated water temperature/Compressor operation time/Fan operation time/Pump operation time |
Water resistance |
IPx4 equivalent |
Vibration resistance |
MIL-STD-810F equivalent |
Safety standard |
CE (low-voltage command, EMC command)、UL(ETL) |
Operation noise level (dB) |
69 |