VSC-1400S
Space saving, compact body, Demonstrate a high cooling capacity.
Specifications
Cooling Method Air-Cooled type Cooling Capacity(W) 1300/1400 Tuning Form/Setting Criteria Room temperature, Body temperature Tuning Form/Control Target Inlet oil temperature, Outlet oil temperature Tuning Form/Tuning Range (°C) For setting the reference temperature, -19.9 ~ 19.9 Non-removable Type/Control Target Inlet oil temperature, Outlet oil temperature Non-removable Type/Control Range (°C) 5-50 Oil Viscosity (mm2)(S) 1.4-200 Usable Oil Types Lube Oil , Hydraulic Mineral Oil Use Area Temperature (°C) 5~50 External Dimensions (mm) H650×W360×D440 Volume (kg) 55 Coating Color Light Beige Munsell No-5Y7.0 / 1 Semi-gloss Rated Voltage (V) Three-phase AC200 Consumption Current (A) 3.6/3.1 Wattage (W) 630/710 Coolant R407C 370g Noise (dB) 60 Pump/Rated Output (W) 400 Pump/Exhaust Volume (ℓ/min) 12/14.4 Relief Valve Pressure Setting (MPa) 0.6 Pipes/Oil Inlet Connection Diameter Rc3/4 Pipes/Oil Outlet Connection Diameter Rc3/4 Pipes/Oil Drain Connection Diameter Rc1/8 Safety Circuit/Compressor Temperature protector, Overcurrent relay Safety Circuit/Refrigeration Cycle High pressure switch Safety Circuit/Pump Overcurrent relay, Relief valve Safety Circuit/Circuit Board Fuse Input-Output/Alarm Output Equipment abnormalities, Condensing temperature anomaly Input-Output/Circulation Oil Temperature Output Upper temperature limit, Lower limit temperature, Upper and lower limit temperature (2 points) Input-Output/Control Input Operation is stopped Compressor operation, Pumping operation Input-Output/External Thermista 2W (Optional) Input-Output/RS-232C 3W